2400-BPS Internal Modem (250-3025B) Specifications Faxback Doc. # 5788 Modem Compatibility:...........................CCITT V.22 bis at 2400 bps Bell 212A and CCITT V.22 at 1200 bps Bell 103J at 300 bps Command Compatibility:......................Hayes Extended AT command set Modem Data Rates:................................ 2400, 1200, and 300 BPS SPEED SELECTION: Originate Mode:..........................Automatic on attention character Answer Mode:..................Automatically set to speed of incoming call Test Modes:.......................................Analog (local) loopback (both initiate and respond) Software command controlled Receiver Sensitivity:.............................................-43 Dbm Transmit Level:...................................................-10 Dbm Line Impedance:..................................................600 Ohms Error Rate:...........................................1 in 105 characters on standard 3002 unconditioned line Modulation:.........................300 bps: Frequency shift keyed (FSK) 1200 bps:...........................differential phase shift keyed (DPSK) 2400 bps:...................................16-point quadrature amplitude modulation/Phase-shift keyed (QAM/PSK) DAILING: Pulse:....................................................Rotary (10 pps) Tone:................................................. Including * and #, Duration:..............................................95 ms (adjustable) Command Buffer:.............................................42 characters Operating Temperature:..............................32 TO 104F (0 TO 40C) Storage Temperature:............................-40 t +176F (-40 to +80C) Humidity:............................................0-90% Non-condensing (SMC/all-07/13/94)