360K Floppy Drive (250-4051/A/B) Settings Faxback Doc. # 5262 NOTE: The below jumper settings and information are for the 250-4051 and 250-4051A only. For the 250-4051B, refer to the section following this one. NOTES & JUMPERS: DS1 Both floppy drives in system use DS1 as the cable selects the drive HC Causes head load with door close DC Resets status on falling edge of step pulse MM Selects active low motor on TERMINATION: The terminating resistor pak should be installed at location B6 on the last drive on the cable. The termination resistor is a 150 ohm, 8 resistor 16-pin dip (Cat #25- 3000A; Part # ARX-0397). DIAGNOSTICS: These are available through National Parts - AXX-2053 Tandy 3000 Diagnostic Disk AXX-2046 Double-sided, 40-track Alignment Disk NOTE: The below jumper settings and information are for the 250-4051B. For the 250-4051 and 250-4051A, refer to the section preceding this one. NOTES & JUMPERS: DS1 Both floppy drives in system use DS1 as the cable selects the drive MM Spindle motor power controlled by 'MOTOR ON' signal TERMINATION: The last drive on the cable should be terminated with a 16-pin dip, 150ohm resistor package (Cat #25-4001; Part # ARX-0040). DIAGNOSTICS: These are available through National Parts - AXX-2052 Diagnostic Disk AXX-2054 Alignment Disk (dtc-08/02/93)