WP-101 (260-3970) Error Messages Faxback Doc. # 5194 Card is write-protected. The card memory you are using is write-protected. Remove the write protection or use another card memory. Carriage does not word properly. Turn the power switch off and then on again. Turn off the word processor and then turn it on again. If the error message still appears, contact your local Radio Shack Computer Center or store. Directory is full of files. You attempted to store text when the built-in memory or the card memory already contains the maximum number of files. Delete any unnecessary files on that store memory to make room for more, use the other store memory, or use another card memory. File is not found. You attempted to recall, delete, or rename a file that is not in the built-in memory or on the card memory. Select the store memory that contains the file you want. Inadequate COPY/MOVE memory. The copy/move memory is actually part of the work memory. The remaining work memory is too small to store the text you want to copy. Inadequate store memory space. You attempted to store more text than will fit in the available store memory space in the built-in memory or on the card memory. Delete any unnecessary files on that store memory to make room for the text, use the other store memory, or use another card memory. Inadequate work memory. COPY/MOVE memory will be automatically cleared when COPY/MOVE is executed. Do you want to execute COPY/MOVE? (Y/N). The remaining work memory is sufficient to store marked text, but not great enough to in- sert or copy it. Press Y to execute copying/moving. The copy/move memory is cleared to make room for the text you are inserting. Press N to cancel the copy/move function. The contents of the copy/move memory are not deleted. No card is in the slot. There is no card memory in the card memory slot. Insert a card memory into the slot. No text to print. You attempted to print when there is no text in the work memory. Recall a file from the built-in memory or the card memory, or type new text before printing. Remaining work memory is inadequate for the file. You attempted to recall a file from the built-in memory or the card memory when there is already text in the work memory and the remaining space available in the work memory is inadequate for the file. To make room for the recalled file, store the text currently in the work memory to one of the store memories and/or clear the work memory. Then, recall the file. Store memory read error. The card memory has not been initialized yet, or there is something wrong on the card memory or in built-in memory. Use a properly initialized card memory. If you see this message when you are accessing the built-in or initialized card memory, copy to the other store memory the files that the WP-101 can read. Then, reinitialize the store mem- ory from which the files were copied. Work memory is full. This message appears under three different conditions: * The remaining work memory goes to one percent or below and there is no text in either the copy/move memory or the undelete buffer. The error message appears once; after that, a beep sounds each time you press a key. * The remaining work memory is 60 characters or less, there is text in either the copy/move memory or the undelete buffer, and you press N at the prompt; Do you want to clear COPY/MOVE memory to obtain space for more text to enter? A beep sounds and the error message appears each time you press a key. * The remaining work memory is 60 characters or less and there is no text in either the copy/move memory or the undelete buffer. A beep sounds and the error message appears each time you press a key. Work memory is full. Do you want to clear COPY/MOVE memory to obtain space for more text to enter? (Y/N). The remaining work memory goes to one percent or below while there is text in either the copy/move memory or the undelete buffer. Press Y to clear the copy/move memory and the undelete buffer. Press N and the text is not cleared. The work memory counter in the status area reads 1% and a beep sounds each time you press a key. GRAMMAR CHECK MESSAGES The WP-101 checks several points to detect grammatical errors in spacing, capitalization, and punctuation throughout your document. When an error is found, the message tells you which type of error it is. Beginning error? There is an invalid symbol at the beginning of the sentence. Delete the incorrect character. )Thank you very much for your letter Thank you very much for your letter Capitalization error? The first character of the sentence is not capitalized. Change the first character to a capital letter. we are not standing still We are not standing still Double word? The same word is typed twice in a row. Delete either one. in our product line line for in our product line for Punctuation error? There is an unreasonable usage of successive punctuation marks. Delete unnecessary punctuation or change the incorrect punctuation mark. We wait for your reply.! We wait for your reply! Quotation error? There is unusual punctuation after the quotation mark. Delete the unnecessary punctuation. ")Meeting the New Market" "Meeting the New Market" Spacing error? a) There is no space after the comma or semicolon. Insert a space after the command or semicolon. for your continued patronage,we have for your continued patronage, we have b) There are two spaces between two words (except at the end of a sentence). Remove the extra space. The market will continually grow The market will continually grow c) The number of spaces before and after a dash is not correct. Space once before and once after the dash or do not space either before or after the dash. It is --as many tools are It is -- as many tools are d) The number of spaces before and after a colon is not correct. Do not type a space before the colon: type one or two spaces after the colon. Example :Los Angeles, Tokyo Example: Los Angeles, Tokyo (css 08/04/93)